1) Fill in the weight box with your weight in kilos without decimal places
2) Fill in the RVM box with your open circuit average consumption in litres given on the surface without using decimal digits
3) Fill in the box relating to the counter-lung ratio, indicating the denominator of the ratio between the volume of the dump counter-lung and the volume of the counter-lung containing the gas to be reused
4) Fill in the fractions of Oxygen and Helium using at most one decimal place
5) There are 2 decimal places you can use in the oxygen partial pressure range you wish to study. The intervals range from 0.10 to 1 and from 0.8 to 2.2
6) Select the absorbent used and fill in the quantity field using a maximum of two decimal places. Increments are 250 grams
7) The type of dive, whether relaxed or strenuous, uses the Metabolic Equivalent of Task system at a rate of 3 and 4.5 respectively
8) Fill in the Altitude box by typing the surface altitude (in meters) of the body of water where you dive
9) Finally, fill in the Step value box with the metric rate of increase you want the study to follow
10) Optional: If you would like guidance on how to follow the rule of thirds (cave) with the pSCR, please fill in the appropriate section. You must use the divisor of your Effective Efficiency with your pSCR and indicate the bars, or total available litres. If both boxes are filled in correctly, once you click on the Submit button, the first table presented is the indication for the rule of thirds: bars if you have used bars, litres if you have entered the quantity in litres
11) Optional – Deco Gases & Control Average: After calculating the mix, if the gas is used as a bottom gas and contains Helium, a link appears in the Results header. Click it to expand the deco section. Enter the maximum depth at which the mix will be used and the planned bottom time. The system calculates X = FHe × ATA × time and indicates: how many deco gases to plan, and the control average (% O₂) to verify at 6 m before the final ascent. If X exceeds 340, the exposure falls outside the tabulated range and an individual calculation is required.
Results: Once you click on the Submit button, you get two or three tables. If the Caves section has been filled in, the first table contains the indications to be followed for the rule of third with pSCR, the software suggests the maximum amount of bars or litres that can be consumed with the pSCR in order to be able to go out in two breathing in open circuit; the second shows a range of gas data such as O₂ consumption, CO₂ production, assumed scrubber life and hourly calorie burning. The third table lists the study of the mix according to the parameters set.
Some rows may have values written in red. This tells us that at that depth the safety and/or set parameters are exceeded.
Safety parameters that cannot be changed include:
• Nitrogen Partial Pressure which must not exceed 3.2
• Mix Density which must not exceed 6.2 g/l
• Oxygen Partial Pressure which must remain between 0.16 and 1.4 as it is still a pSCR
Please note that the indicated scrubber life is a pure arithmetic calculation assuming ideal conditions. Actual service life may differ considerably depending on conditions of use
Be sure to fully understand how pSCR works and the reasons for the Oxygen Drop before using this software. The calculated values refer to a correct use of the pSCR. Poorly adjusted exhaust valve, excessive nose exhaled gas, incorrect timing of loop flushes, incorrect nose exhalation during ascent, just to name a few examples, greatly influence Oxygen Drop.
Please do not use this software to study the behaviour of apparatus other than pSCRs, it would give completely erroneous and dangerous results!
We took great care in developing and writing the software, but mistakes are always possible. Therefore, we cannot take responsibility for any accidents or incidents that may occur when using this software. However, we would be grateful if you would point out any errors, oversights, inaccuracies and anything else that might limit the use of the Touzil System
The history of the project and the full disclaimer are under History & Disclaimer, at the top of the page.
Touzil System V. 2.6, November 2026
Started in 2007, the Touzil System Project is a continuous effort to better understand Oxygen Drop in pSCR diving and to develop better and safer pSCR diving.
Notice that when diving a pSCR rebreather a reduction in inspired FO₂, oxygen percentage in the Mix, occurs on each breath until just a portion of fresh gas is injected and partially raises the Mix FO₂. This is referred as "Oxygen drop", which ends up reducing the Minimum Operating Depth of a given Mix, when compare to Open Circuit.
Oxygen Drop is one of the main risk factors in this unit type.
Oxygen Drop theory is paramount in the safety of pSCR diving, as the mechanics of rebreather diving affect gases properties. Furthermore the diver breathing efficiency and the real rebreather ratio plays key role in the true Oxygen Drop.
We developed the Touzil System, a proprietary software that can predict the Oxygen Drop and the consequent increase in the fraction of inert gases. The results provided by this software depend on the user and rebreather efficiency combinations. Both under workload and at rest. The density of the breathed mix is also calculated with an indication of whether the limits suggested by the Anthony and Mitchell studies have been exceeded.
This is the second version of the Touzil System; it is completely revamped and also adds the prediction of inert gas trends and scrubber life.
We recommend the application of PO₂ / FO₂ monitoring devices at least until full understanding of Oxygen Drop.
Prediction is challenging especially if the gas is changing during the dive, both in bottom and decompression phase, as it does on pSCR diving. Furthermore your average Open Circuit decompression rules will not mirror your rebreather needs, and could end up becoming inefficient for proper decompression. In fact DCS in not well trained pSCR rebreather divers is quite common. As of today decompression theory in general is still not a full understood science.
Get proper rebreather training. Don't just get the c-card, get someone that actually dive extensively the unit in your conditions. Also dive within your training limitations, a No Decompression Limit rebreather course is not intended to cover rebreather Trimix diving.
We took great care in developing and writing the software, but mistakes are always possible. In fact, they are always lurking. Therefore, we cannot take responsibility for any accidents or incidents that may occur when using this software. However, we would be grateful if you would point out any errors, oversights, inaccuracies and anything else that might limit the use of the Touzil System.
Touzil System v. 2.6, November 2026